Datasheets

Datasheets, no sign-up.

View, print or download each datasheet (.txt or .csv): full characteristics, revision, date and indicative price excluding VAT.

6 datasheets shown

SAE-TLG4 · rev. C · 15/09/2026

Solar telemetry cabinet for boreholes

Monitors level, flow and pressure of a remote borehole and alerts you, on battery, even after three days without sun.

from 2,850,000 FCFA (≈ €4,345)

Technical characteristics
Solar telemetry cabinet for boreholes
PLCCompact, to your standard
Inputs / outputs8 TOR · 6 TOR · 4 × 4–20 mA
Communication4G LTE-M + SMS · LoRaWAN (option) · MQTT TLS
Power24 V CC · 100 Wc · LiFePO4 40 Ah
Autonomy without sun3 days
EnclosurePolyester IP66, 600 × 400 × 250 mm
Temperature−10 à +55 °C
ProtectionSurge arresters, dry-run protection
MeasurementsLevel, flow, pressure, run/fault, intrusion
Lead time4 to 6 weeks
Request a quote

SAE-EDGE2 · rev. C · 15/09/2026

Industrial IIoT gateway

Reads your existing PLCs, keeps 30 days of data locally and forwards it encrypted.

from 1,450,000 FCFA (≈ €2,211)

Technical characteristics
Industrial IIoT gateway
Compute4 cœurs · 4 Go RAM · 32 Go eMMC
Network2 × Ethernet 1 Gbit/s · RS-485 · RS-232 · 4G (option)
ProtocolsModbus RTU/TCP · OPC UA client/serveur · MQTT TLS 1.2+ · S7 · EtherNet/IP
Local buffer30 days (500 variables at 10 s)
SecuritySecure boot, firewall, named accounts, signed updates, IEC 62443 principles
Power24 V CC (9–36 V) · 8 W
MountingDIN rail
Temperature−20 à +60 °C
Request a quote

SAE-CP2 · rev. C · 15/09/2026

Duty/standby 2-pump control cabinet

Two pumps, one pressure setpoint: automatic changeover and full protections.

from 6,900,000 FCFA (≈ €10,519) for 2 × 11 kW

Technical characteristics
Duty/standby 2-pump control cabinet
Power2 × 5.5 à 2 × 45 kW
ControlDrives, automatic changeover, pressure PID
ProtectionThermal, dry-run, overvoltage, imbalance
HMI7" touch
EnclosureSteel IP55, filtered ventilation, tropicalised boards
DesignTo IEC 61439-2
CommunicationModbus TCP
Request a quote

SAE-ATS400 · rev. C · 15/09/2026

Mains / generator transfer switch

Starts the generator and transfers the load within seconds, then restarts loads in sequence.

from 4,200,000 FCFA (≈ €6,403)

Technical characteristics
Mains / generator transfer switch
Rating400 A · 4 pôles
Transfer time8 à 15 s, generator start included
RestartSequential load restart
MeteringEnergy, voltage, current
CommunicationModbus
Generator testMonthly, automatic
Request a quote

SAE-TRS · rev. C · 15/09/2026

Line supervision & OEE pack

The OEE of every shift, without data entry, with the cause of every stop, on a shop-floor screen.

from 9,500,000 FCFA (≈ €14,483) per line

Technical characteristics
Line supervision & OEE pack
Scope1 line, up to 8 machines
CollectionAutomatic states and stop causes
KPIsPer-shift OEE (A × P × Q)
Shop-floor screen43"
ReportsDaily · CSV export
Commissioning3 weeks
Request a quote

SAE-MCO · rev. C · 15/09/2026

Maintenance and on-call contracts

Three service levels, written response times and a 12-month term stated up front.

from 290,000 FCFA/month (≈ €442)

Technical characteristics
Maintenance and on-call contracts
Essential2 preventive visits a year, support in business hours 290,000 FCFA/month (≈ €442)
Continuity4 visits, 24/7 on-call, written response times 690,000 FCFA/month (≈ €1,052)
PerformanceContinuity + remote alarm monitoring, monthly report, critical spares in stock 1,250,000 FCFA/month (≈ €1,906)
Reference1 site, 5 PLCs
Term12 months; 3 months’ notice
Request a quote

Indicative prices excluding VAT, installation and travel beyond the Littoral region. Your exact price appears in an itemised quote. VAT extra (19.25% in Cameroon, 20% in France). Brands are mentioned as compatible technologies.

Deliverables

What we deliver on every project

  • Functional specificationThe “what”, written and approved before coding.
  • DrawingsElectrical, wiring and network architecture.
  • Commented source codePLC and SCADA, handed over at acceptance.
  • As-built file (DOE)The installation as it truly is.
  • Operating manualIn French and English.
  • Maintenance planWho does what, and how often.
  • FAT and SAT reportsEvery test traced and signed.
  • TrainingOperators and maintenance, on your installation.

Industry words, explained

Glossary

TRS / OEE
Overall equipment effectiveness: the share of time the line produces well, at the right pace (availability × performance × quality).
SCADA
Supervisory control and data acquisition: the screen that shows the plant and keeps its history.
IHM / HMI
Human-machine interface: the touch screen or workstation where the operator works.
E/S / I/O
Inputs and outputs: the signals a PLC reads or drives.
FAT
Factory acceptance test, on a simulator, with the client present.
SAT
Site acceptance test, once the installation is connected.
OPC UA
Standard, secure protocol for exchanging data between industrial equipment and software.
MQTT
Lightweight protocol for sending measurements, suited to slow networks.
MCO
Lifecycle support: everything that keeps the installation available over time.
DOE
As-built file: drawings and manuals of the installation as built.
ISA-18.2
Alarm management standard: states, priorities, rationalisation.
ISA-101
Operator interface standard: restrained screens, colour reserved for abnormal situations.

Next step

Let’s talk about your plant.

An engineer replies within one business day. And if a plant is down, call the on-call line: someone answers.